Fluke 434 3 Phase Power Quality Analyser

$3,150

Model : 434 3 Phase Analyser

 

SKU: 288 Category: Tag:

Description

Fluke 434 3 Phase Power Quality Analyser

 

Fluke 434 3 Phase power quality meter help you locate, predict, prevent and troubleshoot problems in power distribution systems. These easy-to-use power quality tools are a モmust haveヤ for any person who maintains or troubleshoots three phase power. The new IEC Class A standards for flicker and power quality are built right in to take the guess work out of power monitoring.

 

Applications Fluke 434 3 Phase

  • Frontline troubleshooting ヨ quickly diagnose problems on-screen to get your operation back online
  • Predictive maintenance ヨ detect and prevent power quality issues before they cause downtime
  • Quality of service compliance ヨ validate incoming power quality at the service entrance
  • Long-term analysis ヨ uncover hard-to-find or intermittent issues
  • Load studies ヨ verify electrical system capacity before adding loads
  • Energy assessments ヨ quantify energy consumption before and after improvements to justify energy saving devices

 

Fluke 434 3 Phase Energy Analyzer offer the best in power quality analysis and introduce, for the first time ever, the ability to monetarily quantify energy losses.

  • Energy loss calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint true system energy losses in dollars (other local currencies available).
  • Power inverter efficiency: Simultaneously measure AC output power and DC input power for power electronics systems using optional DC clamp.
  • PowerWave data capture: capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
  • Waveform capture: capture 100/120 cycles (50/60Hz) of each event that is detected in all modes, without set-up.
  • Automatic Transient Mode: capture 200 kHz waveform data on all phases simultaneously up to 6 kV.
  • Fully Class-A compliant: conduct tests according to the stringent international IEC 61000-4-30 Class-A standard.
  • Mains signaling: measure interference from ripple control signals at specific frequencies.
  • Troubleshoot real-time: Analyze the trends using the cursors and zoom tools.
  • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
  • Measure all three phases and neutral: With included four flexible current probes with enhanced thin flex designed to fit into the tightest places.
  • Automatic Trending: Every measurement is always automatically recorded, without any set-up.
  • System-Monitor: Ten power quality parameters on one screen according to EN50160 power quality standard.
  • Logger function: Configure for any test condition with memory for up to 600 parameters at user defined intervals.
  • View graphs and generate reports: With included analysis software.
  • Battery life: Seven hours operating time per charge on Li-ion battery pack.

 

Features Fluke 434 3 Phase

  • Troubleshoot real-time: Analyze the trends using the cursors and zoom toolsラeven while background recording continues
  • Highest safety rating in the industry: 600 V Cat IV/1000 V CAT III rated for use at the service entrance
  • Automatic transient mode: Captures 200 kHz waveform data on all phases simultaneously: Up to 6 kV
  • Fully Class A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class A standard
  • Measure all three phases and neutral: With included four current probes
  • AutoTrend: Every measurement you see is always automatically recorded, without any setup
  • System-monitor: Up to seven power quality parameters on one screen according to EN50160 power quality standard
  • Inrush mode: For troubleshooting nuisance circuit breaker tripping
  • View graphs and generate reports: With included analysis software
  • Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals
  • Mains signaling: Measure interference from ripple control signals at specific frequencies
  • Battery Life: Seven hours operating time per charge on NiMH battery pack
  • Warranty: Rugged, handheld troubleshooter with 90 Day warranty

 

Additional Information

Installed Options:
– Transients
– Inrush
– Interharmonics
– Energy
– Memory
– Mains Signaling

 

Specifications Fluke 434 3 Phase

Inputs
Number:  4 voltage and current (3 phases + neutral)
Maximum voltage:  1000 Vrms (6 kV peak)
Maximum sampling speed:  200 kS/s on each channel simultaneously
Volt/Amps/Hertz
Vrms (AC + DC)
Measurement range:  1 … 1000 V
Accuracy:  0.1% of Vnom
Vpeak
Measurement range:  1 … 1400 V
Accuracy:  5% of Vnom
Crest factor, voltage
Measurement range:  1.0 … > 2.8
Accuracy:  ±5%
Arms (AC + DC)
Measurement range:  0 … 20 kA
Accuracy:  ±0.5% ± 5 counts
Apeak
Measurement range:  0 … 5.5 kA
Accuracy:  5%
Crest factor, A
Measurement range:  1 … 10
Accuracy:  ±5%
Hz 50 Hz nominal
Measurement range:  40 … 70 Hz
Accuracy:  ±0.01 Hz
Dips and swells
Vrms (AC+DC) ²
Measurement range:  0.0% ナ 100% of Vnom
Accuracy:  ±0.2% of nominal voltage
Arms (AC+DC) ²
Measurement range:  0 … 20 kA ?
Accuracy:  ±1% ± 5 counts
Harmonics
Harmonic (interharmonic) (n)
Measurement range:  DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7
Vrms
Measurement range:  0.0 ナ 1000 V
Accuracy:  ±0.05% of nominal voltage
Arms
Measurement range:  0.0 ナ 4000 mV x clamp scaling
Accuracy:  ±5% ± 5 counts
Watts
Measurement range:  Depends on clamp scaling and voltage
Accuracy:  ±5% ± n x 2% or reading, ± 10 counts
DC voltage
Measurement range:  0.0 ナ 1000 V
Accuracy:  ±0.2% of nominal voltage
THD
Measurement range:  0.0 ナ 100.0%
Accuracy:  ±2.5% V and A (± 5% Watt)
Hz
Measurement range:  0 ナ 3500 Hz
Accuracy:  ± 1 Hz
Phase angle
Measurement range:  -360º … +360º
Accuracy:  ± n × 1.5º
Power and energy
Watt, VA, VAR
Measurement range:  1.0 ナ 20.00 MVA¹
Accuracy:  ±1% ± counts
kWh, kVAh, kVARh
Measurement range:  00.00 ナ200.0 GVAh¹
Accuracy:  ± 1.5% ± 10 counts
Power Factor/ Cos ? / DPF
Measurement range:  0ナ1
Accuracy:  ± 0.03
Flicker
Pst (1 min), Pst, Plt, PF5
Measurement range:  0.00 ナ 20.00
Accuracy:  ±5%
Unbalance
Volts
Measurement range:  0.0 ナ 5.0%
Accuracy:  ±0.5%
Current
Measurement range:  0.0 ナ 20%
Accuracy:  ± 1%
Transient Capture
Volts
Measurement range:  ±6000 V
Accuracy:  ±2.5% of Vrms
Minimum detect duration  5 µs (200kS/s sampling)
Inrush mode
Arms (AC+DC)
Measurement range:  0.000 ナ 20.00 kA¹
Accuracy:  ±1% of meas ± 5 counts
Inrush duration (selectable)
Measurement range:  7.5 s … 30 min
Accuracy:  ±20 ms (Fnom = 50 Hz)
Autotrend recording
Sampling:  5 readings/sec continuous sampling per channel
Memory:  1800 min, max and avg points for each reading
Recording time:  Up to 450 days
Zoom:  Up to 12x horizontal zoom
Memory
Screens & data:  50, shared memory divided between logging, screens and data sets
Notes
¹  Depending on clamp scaling
 Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle

 

 

Package include :

  • Fluke 434 HandHeld Power Quality Analyzer
    • Installed Options:
      • Transients
      • Inrush
      • Interharmonics
      • Energy
      • Memory
      • Mains Signaling
  • (4) Fluke i400S AC Current Clamps
  • AC Adapter/Charger
  • User Manual On CD-ROM
  • Carrying Case

 

 

Additional information

Lead Time

5-7 days

Packaging

Box

Brand

Fluke

PRODUCT INQUIRY

Please enable JavaScript in your browser to complete this form.

Reviews

There are no reviews yet.

Be the first to review “Fluke 434 3 Phase Power Quality Analyser”

Your email address will not be published. Required fields are marked *