Fluke QA-ES II Electrosurgical Analyzer

$3,250

Model : QA-ES II Aanalyzer

 

SKU: 293 Category: Tag:

Description

Fluke QA-ES II Electrosurgical Analyzer

 

Fluke QA-ES II analyzes electrosurgical units quickly and accurately. A wide load-resistance range provides 128 user-selectable loads, including very low loads for testing many of today’s ESUs.An accuracy of ±5 % of reading down to 20 mA guarantees reliable high-frequency leakage results. With capability to run an automatic power- distribution test in as little as 1 minute, the QA-ES II works fast so technicians save time.An Ansur QA-ES software plug-in allows users to create and automatically run tests, capture data, and produce easy-to-read reports with a PC.

The unit may exhibit minor cosmetic blemishes and a small crack at the corner, but these do not impede the screen’s performance or visibility.

All buttons are in proper working condition. It’s a reliable and durable piece of equipment that has been thoroughly tested for optimal performance. Despite minor cosmetic flaws, this electrosurgical tester still functions perfectly, so you can trust its results.

Every button is functional and the display is clear, making it an exceptional choice for precision and accuracy.e images.

 

Key Features  Fluke QA-ES II

  • Fluke QA-ES Series II Electrosurgery Analyzer analyzes electrosurgical units quickly and accurately
  • A wide load-resistance range provides 128 user-selectable loads, including very low loads for testing many of today’s ESUs
  • An accuracy of ± 2 % of reading down to 20 mA guarantees reliable high-frequency leakage results. With a capability to run an automatic-power-distribution test in as little as 1 minute, the Fluke QA-ES Series II Electrosurgery Analyzer works fast so technicians save time
  • An Ansur QA-ES software plug-in allows users to create and automatically run tests, capture data, and produce easy-to-read reports with a PC
  • Automatic power distribution measurement, including power, current, peak-to-peak voltage (closed load only), and crest factor
  • Oscilloscope output
  • High-frequency leakage measurements with an accuracy of ± 2 % of reading
  • 128 internal user-selectable test loads from 10 Ω to 5,200 Ω
  • Foot-switch output for triggering the ESU under test
  • Large display
  • RS-232 and Centronics Printer interface
  • Automatic power distribution measurement, including power, current, peak-to-peak voltage (closed load only), and crest factor
  •  Oscilloscope output
  •  High-frequency leakage measurements with accuracy of ± 2 % of reading
  •  128 internal user-selectable test loads from 10 Ω to 5200 Ω
  •  Foot-switch output for triggering the ESU under test
  •  Ansur QA-ES software plug-in for automated test protocols
  •  Large display
  •  RS-232 and Centronic-Printer interface

 

Specifications

  • Operating Temperature: 59 °F to 95 °F
  • Storage Temperature: 32 °F to 122 °F
  • Humidity: 80% non-condensing
  • Display Type: LCD
  • Alphanumeric format: 8 lines, 40 characters
  • Graphics mode: 240 x 64 point matrix
  • Controls: Function keys F1 through F5, ENTER, CANCEL, and an encoder control
  • Interfaces: Parallel printer port; bi-directional RS232 for computer control
  • Electrical Info: 115 – 230 VAC | 48 – 66 Hz | 35 W
  • Mechanical Specifications Housing: Metal case
  • Dimensions: 13 1/2″ W x 15 1/2″ D x 5 1/3″ H
  • Weight: 22 lbs

 

Technical Specifications :

  • General Output.

– Continuous Operation. 

Continuous measurement of power, current, peak to peak voltage (close load only), and crest factor.

 – Single Operation.

Single measurement after the set delay time of the ESU out put of power, current, peak to peak voltage                    (close load only), and crest factor.

– Power Distribution

Automatic measurement of power current, peak to peak voltage (close load only), and crest factor trough                the user selectable load range.

– RF leakage current

Provide connections and configurations to measure HF leakage from both grounded and isolated                              equipment.

  – RECQM

Test the “return electrode control quality monitoring” using the QA ES internal loads.

  • Model of operations : Manual or remote controlle (via Ansur)
  • Measurements : True-rms value of applied waveform
  • RMS bandwith : – 30 Hz to 10 MHz (-dB) for instrumentation only. – 30 Hz to 2,5 MHz (-3dB) with loads.
  • Low frequency filter : 100Hz filter to avoid low-frequency disturbance or inteference.
  • Current : 20mA to 2200 mA (+- 2%) of reading
  • Load resistance : – 10 ohm to 2500 ohm in step of 25 ohm  and – 2500 ohm to 5200 ohm in step of 100 ohm
  • Additional fixed load : 200 ohm 400 W for 30 s. Max 15 % duty cycle.
  • Crest factor : The higher of two peak voltage measurement is used for computation.
  • Range : 1,4 to 16 (V peak/ V rms).
  • Foot-switch output : The foot switch output can be used to trigger the elecreosurgical unit.
  • Peak-to-peak voltage : – 0 kV to 10 kV (closed load only). Accuracy +- 10%.
  • Oscilloscope output : 5V/A uncalibrated, 100 mA RF current minimum input.
  • Ansur QA-ES Plug In : – User-programmable test sequences : Allow unlimited number of test sequences with user programmable templates and test limit. These test include power distribution test, output test, HF leakage, and RECOM verification.
  • Remote control : All function and test in QA-ES maybe performed from PC.
  • Storage and Recall : Protocol formats and data maybe stored, recalled, printed out, or transfered.
  • Storage : 0° C to 50° C ( 32° F to 122° F)
  • Temperature operating : 15° C to 35° C ( 59° F to 95° F)
  • Display : LCD graphic display
  • Alphanumeric format : 8 line x 40 characters.
  • Graphic mode : 240 x 64 pixel matrix.
  • Display Control : 5 F-key, enter, cancel, control knob and encoder.
  • Data inputs/outputs : Pararell printer port and bidirectional RS-232
  • Power : 115-230 V ac, 48 Hz to 66 Hz , 35 VA.
  • Housing : Metal case.
  • Dimensions ( W x D x H ) : 39,5 cm x 34,2 cm x 13,2 cm.
  • Weight : 9,8 kg (21,6 lbs)

 

Depend on the QA-ES II Electrosurgical Analyzer for complete ESU preventive maintenance, and safety testing of all critical functions. Collect all measurements including vessel sealing, contact quality monitor (CQM), high frequency (HF) leakage and output power distribution in single or continuous mode.

The QA-ES II has all hardware and software needed for complete testing, so you don’t need to carry additional accessories or cables. With all-inone features, data storage, wireless functionality, the QA-ES II is one of the most user-friendly electrosurgical analyzers on the market today.

Additionally, Ansur test automation software automates testing and allows users to create and automatically run tests, capture data, and produce easy-to-read reports.

 

Continuous operation – Continuous measurement of power, current, peak-to-peak voltage (closed load only), and crest factor

Single operation – Single measurement after the set delay time of the ESU output of power, current, peak-to-peak voltage (closed load only), and crest factor

Power distribution – Automatic measurement of power, current, peak to-peak voltage (closed load only), and crest factor through a user-selectable load range

RF leakage current – Provides connections and load configurations to measure HF leakage from both grounded and isolated equipment

RECQM – Test the “return electrode control quality monitoring” using the QA-ES internal loads

 

Package Include :

  • Fluke Biomedical QA-ES2 Electrosurgery Analyzer
  • Power Cord
  • User Manual On CD-ROM

 

Additional information

Lead Time

5-7 days

Packaging

Box

Brand

Fluke

PRODUCT INQUIRY

Please enable JavaScript in your browser to complete this form.

Reviews

There are no reviews yet.

Be the first to review “Fluke QA-ES II Electrosurgical Analyzer”

Your email address will not be published. Required fields are marked *