Fluke ESA620 115 VAC Electrical Safety Analyzer

$2,350

Model : ESA620 115 VAC Safety Analyzer

 

SKU: 684 Category: Tag:

Description

Fluke ESA620 115 VAC Electrical Safety Analyzer

 

Fluke ESA620 115 VAC Electrical Safety Analyzer, featuring smart technology to enhance productivity under any standard, represents the next generation in portable electrical safety testers. With selections of three test loads, two protective earth test currents and two insulation test voltages, this versatile device performs all primary electrical safety tests as well as several additional leakage tests for premium standards compliance worldwide.

A convenient 20 A device receptacle broadens the range of equipment that can be tested using the Fluke ESA620 115 VAC. Standard 2-wire and optional 4-wire protective earth measurement capabilities offer first-rate time savings, while new DSP technology offers better accuracy of leakage measurements throughout specified ranges.

Equipped with ten unique safety-enhanced ECG posts, Fluke ESA620 115 VAC offers simulation of ECG and performance waveforms so both electrical safety and basic tests on patient monitors can be performed with a single connection. When combined with optional Ansur computer-based software, Fluke ESA620 115 VAC allows for test procedure automation, the capture of results and comparison to standard limits, printed reports, and total digital data management.

 

Comprehensive electrical safety testing to global standards with the ESA620: the preferred test tool for IEC60601-1 compliance

The ESA620 Electrical Safety Analyzer represents quality excellence in manual preventive maintenance for the biomedical technician and clinical engineer that perform tests on medical equipment. With selections of three test loads, protective earth test currents, and two insulation test voltages this versatile product can be used worldwide to test to their standard of choice.

Equipped with ten ECG posts, the ESA620 simulates of ECG and performance waveforms so both electrical safety and basic tests on patient monitors can be performed with a single connection. This full-featured electrical safety analyzer comes standard with test leads for 2-wire protective earth measurements, and with optional leads offers the time-saving 4-wire technique. Additionally, the 25-A-device receptacle allows for testing of those devices that need it, so the technician is not limited to only test 15-A equipment. (US only) New DSP technology offers better accuracy of leakage measurements throughout the ranges specified in the standards, and an intuitive interface guides the user through tests.

The ESA620 features a large display to facilitate quick and clear indication of performed tests, criteria associated with test set up, device under test receptacle conditions and results. The unit is equipped with standard USB interface for computer control and data transfer. When used with optional Ansur computer-based software Plug-in, the ESA620 allows for standardization of test procedures, as well as result capturing, storage and printing of reports.

When combined with Ansur, the ESA620 can be automated, capturing results and comparing them to standard limits, essentially enabling this manual unit the sophisticated performance of high end electrical safety equipment at half the price.

 

Features Fluke ESA620 115 VAC

  • Superior compliance with multiple standards: IEC60601:2005, EN62353, VDE 751, ANSI/AAMI ES1:1993, NFPA-99, AN/NZS 3551, IEC61010
  • Three test loads
  • Expanded leakage ranges through 10,000 µA
  • Dual-lead resistance, leakage, and voltage tests
  • AC only, dc only and true-rms leakage readings
  • 100 % and 110 % mains voltage for mains on applied part (lead isolation) test
  • 200 mA and 25 A ac PE test current
  • DSP filter technology for improved accuracy in leakage measurements
  • 20 A equipment current
  • More applied parts selections
  • ECG and performance waveforms
  • Intuitive user interface
  • Easy-to-use applied parts (ECG) connections
  • Insulation posts on applied parts connections
  • Five different insulation tests
  • Varying insulation test voltage 500 V dc and 250 V dc
  • USB connection
  • CE, C-TICK and CSA for USA and Canada
  • RoHS compliance
  • Designed, tested, and built to incomparable Fluke quality standards

 

Specifications Fluke ESA620 115 VAC

Voltage

Range (mains voltage) 90 V to 132 V ac rms
180 V to 264 V ac rms
Range (accessible voltage) 0 V to 300 V ac rms
Accuracy ± (2 % of reading +2 LSD)
Voltage tests Mains, accessible, and point-to-point

Earth resistance

Two-terminal mode test current/range and accuracy > 200 mA ac 0.0 to 2.0 O ± (2 % of reading + 0.015 O)
10 A to 25 A ac 0.0 to 0.2 O ± (2 % of reading + 0.015 O)
0.2 to 2.0 O ± (5 % of reading + 0.015 O)
Four-terminal mode test current/range and accuracy > 200 mA ac 0.0 to 2.0 O ± (2 % of reading + 0.005 O)
10 A to 25 A ac 0.0 to 0.2 O ± (2 % of reading + 0.005 O)
0.2 to 2.0 O ± (5 % of reading + 0.005 O)
Resistance tests Earth resistance and point-to-point

Equipment current

Mode AC rms
Range/accuracy 0 A to 20 A ± 5 % of reading ± (2 counts or .2 A, whichever is greater)
Duty cycle 15 A to 20 A, 5 min on/5 min off
10 A to 15 A, 7 min on/3 min off
0 A to 10 A continuous

Leakage current

Modes AC + DC (True-rms)
AC only
DC only
Patient load selection (input impedance) AAMI ES1-1993
IEC 60601
IEC 61010
Crest factor = 3
Ranges 0 µA to 199.9 µA
200 µA to 1999 µA
2 mA to 10 mA
Frequency response/accuracy DC to 1 kHz
1 kHz to 100 kHz
100 kHz to 1 MHz
± (1 % of reading + 1 µA)
± (2 % of reading + 1 µA)
± (5 % of reading + 1 µA)
Leakage tests Earth (ground wire)
Chassis (enclosure)
Patient (lead to ground)
Patient auxiliary (lead to lead)
Mains on applied part (lead isolation)
Direct equipment
Direct applied part
Alternative equipment
Alternative applied part
Accessible
Point to point
Mains on applied part test voltage 110 % of mains at 230 V for IEC 60601
100 % of mains for AAMI at 115 V per AAMI
100 % of mains at 230 V per 62353

Differential leakage

Ranges 10 µA to 199 µA
200 µA to 1999 µA
2 mA to 20 mA
Accuracy ± 10 % of reading ± (2 counts or 20 µA, whichever is greater)

Insulation resistance

Ranges/accuracy 0.5 MO to 20 MO ± (2 % of reading + 2 counts)
20 MO to 100 MO ± (7.5 % of reading + 2 counts)
Source test voltage 500 V dc
250 V dc
Insulation resistance tests Mains-PE, AP-PE, Mains- PE, Mains-NE (non-earthed accessible conductive part) and AP- NE (non-earthed accessible conductive part)
Mamimum load capacitance 1 µF

ECG performance waveforms

Accuracy ± 2 %
± 5 % for amplitude of 2 Hz square wave only, fixed at 1 mV Lead II configuration
Waveforms ECG complex (BPM) 30, 60, 120, 180, and 240
Ventricular fibrillation
Square wave (50 % duty cycle) (Hz) 0.125 and 2
Sine wave (Hz) 10, 40, 50, 60, and 100
Triangle wave (Hz) 2
Pulse (63 ms pulse width) 30 and 60

Power ratings

Mains voltage outlet 120 V ac 230 V ac
Mains voltage inlet power range 90 to 132 V ac rms 180 to 264 V ac rms
Maximum current 20 A 16 A
Hz 50 or 60 50 or 60

Physical case

Dimensions (L x W x H) 31 cm x 23 cm x 10 cm (12.2 in x 9 in x 2.9 in)
Weight 4.7 kg (10.25 lb)

Environmental specifications

Operating temperature 10 °C to 40 °C
Storage temperature -20 °C to 60 °C
Operating humidity 10 % to 90 % non-condensing
Altitude To 2,000 meters

 

 

Package Includes :

  • Fluke ESA620 115 VAC Electrical Safety Analyzer
  • (2) 1000 Hard Point Test Leads
  • Power Cord
  • USB PC Interface Cable
  • User Manual On CD-ROM
  • Carrying Case (G)

 

Additional information

Lead Time

5-7 days

Packaging

Box

Brand

Fluke