Tektronix DPO7254 Digital Phosphor Oscilloscope

 

Tektronix DPO7254 Digital Phosphor is the new generation of real-time digital phosphor oscilloscopes and are the industry’s best solution to the challenging signal integrity issues faced by designers verifying, characterizing, debugging, and testing sophisticated electronic designs.

The DPO7254 oscilloscope includes as a standard feature a series of user-selectable bandwidth limit filters. These filters preserve the instrument’s bandwidth roll-off characteristics, flatness, and phase linearity within the new frequency range, thereby reducing the effects of out-of-band noise on measurements. Now, designers can purchase one instrument for their highest bandwidth needs and easily optimize it to handle lower-frequency measurements as well.

Tektronix DPO7254 Digital Phosphor Oscilloscope provides turnkey testing & characterization solution for 10GBASE-T measurements as outlined in IEEE 802.3 Section 55, and for 5GBASE-T and 2.5GBASE-T as outlined in IEEE P802.3bz, Section 16; NBASE-T Spec Draft. The industry’s solution to the challenging signal integrity issues faced by designers verifying, characterizing, debugging, and testing sophisticated electronic designs.

 

Key Features Tektronix DPO7254 Digital Phosphor

–   3.5 GHz Bandwidth Model for Serial and Digital Applications
–   2.5 GHz, 1 GHz, and 500 MHz Bandwidth Models for All Applications
–   Up to 40 GS/s Real-time Sample Rate on One Channel and up to 10 GS/s on All Four Channels
–   Up to 500 Megasamples Record Length with MultiView Zoom™ Feature for Quick Navigation
–   >250,000 wfms/s Maximum Waveform Capture Rate
–    Up to 310,000 Waveforms per Second with FastFrame™ Segmented Memory Acquisition Mode
–   User-selectable Bandwidth Limit Filters for Better Low-frequency Measurement Accuracy
–   MyScope® Custom Windows and Right Mouse Click Menus for Exceptional Efficiency
–   Event Search and Mark to Find Specific Events in the Entire Waveform
–   Pinpoint® Triggering provides the Most Flexible and Highest Performance Triggering, with Over 1400                Combinations to Address Virtually Any Triggering Situation.
–   12.1” XGA Display with Touch Screen
–   Communications Mask Testing
–   Clock Recovery from Serial Data Streams
–   64-bit NRZ Serial Pattern Trigger for Isolation of Pattern-dependent Effects up to 1.25 Gb/s
–   Low-speed Serial Protocol Triggering and Decode (I2C, SPI, RS-232, CAN, LIN, and FlexRay)
–   Technology-specific Software Solutions provide Built-in Domain Expertise for MIPI® D-PHY, Ethernet,               USB 2.0 Compliance Testing, Jitter, Timing, Eye Diagram, Power, DDR Memory Bus Analysis, CAN, LIN,             and FlexRay Network Design
–   OpenChoice® Software with Microsoft Windows XP OS enables Built-in Networking and Extended Analysis

 

 

Features & Benefits Tektronix DPO7254 Digital Phosphor

    • 3.5 GHz Bandwidth Model for Serial and Digital Applications
    • 2.5 GHz, 1 GHz, and 500 MHz Bandwidth Models for all Applications
    • Up to 40 GS/s Real Time Sample Rate on One Channel and up to 10 GS/s on All Four Channels
    • Up to 400 Megasamples Record Length with MultiView Zoom™ Feature for Quick Navigation
    • >250,000 wfms/s Maximum Waveform Capture Rate
    • User-selectable Bandwidth Limit Filters for Better Low-frequency Measurement Accuracy
    • MyScope® Custom Windows and Right Mouse Click Menus for Exceptional Efficiency
    • Event Search and Mark to Facilitate the Comprehension of Event Relationships
    • Pinpoint™ Triggering Provides the Most Flexible and Highest Performance Triggering, with over 1400 Combinations to Address Virtually Any Triggering Situation.
    • Small Footprint and Light Weight
    • 12.1” Largest XGA Touch Screen Display in the Industry
    • Communications Mask Testing
    • Clock Recovery from Serial Data Streams
    • 64 bit NRZ Serial Pattern Trigger for Isolation of Pattern-dependent Effects up to 1.25 Gb/s
    • NRZ Serial Test Pattern Triggering
    • Low-speed Serial Protocol Triggering (I2C,SPI, RS-232, CAN)
    • Technology-specific Software Solutions Provide Built-in Domain Expertise for Ethernet, USB 2.0 Compliance Testing, Jitter and Timing Measurements, Power Measurements, CAN and LIN Network Design
    • OpenChoice® Software with Microsoft Windows XP OS Enables Built-in Networking and Extended Analysis

 

Applications Tektronix DPO7254 Digital Phosphor

    • Signal Integrity, Jitter and Timing Analysis
    • Verification, Debug and Characterization of Sophisticated Designs
    • Debugging and Compliance Testing of Serial Data Streams for Telecom and Datacom Industry Standards
    • Low-speed Serial Bus Design (I2C, SPI, CAN, LIN, RS-232)
    • Investigation of Transient Phenomena
    • Power Measurements and Analysis
    • Spectral Analysis

 

Specifications and characteristics Tektronix DPO7254 Digital Phosphor

  • Vertical System:
    • Input Channels:  4
    • Bandwidth (DSP Bandwidth Enhance): 3.5 GHz
    • Rise Time (DSP Bandwidth Enhance): 115 ps
    • Hardware Analog Bandwidth (-3 dB): 2.5 GHz
    • Rise Time 10% to 90% (Typical): 145 ps
    • Rise Time 20% to 80% (Typical): 95 ps
    • DC Gain Accuracy: ±1% with offset/position set to 0
    • Input Coupling: AC, DC, GND
    • Input Impedance (Software selectable):
      • 1 MO ±1% with 13 pF ±2 pF or
      • 50 O ±1%
    • Input Sensitivity:
      • 1 MO: 1 mV/div to 10 V/div
      • 50 O: 1 mV/div to 1 V/div
    • Vertical Resolution: 8 bit (>11 bit with Hi Res)
    • Max Input Voltage:
      • 1 MO: ±150 V CAT I, derate at 20 dB/decade to 9 VRMS above 200 kHz
      • 50 O: 5 VRMS with peaks less than ±24 V
    • Position Range: ±5 divisions
    • Offset Range:
      • 1 mV/div to 50 mV/div: ±1 V
      • 50.5 mV/div to 99.5 mV/div: ±(1.5 V – 10 divisions)
      • 100 mV/div to 500 mV/div: ±10 V
      • 505 mV/div to 995 mV/div: ±(15 V – 10 divisions)
      • 1 V/div to 5 V/div: ±100
      • 5.05 V/div to 10 V/div: ±(150 V – 10 divisions)
    • Offset Accuracy:
      • 1 mV/div to 9.95 mV/div: ±0.2% (offset value-position) ±0.1 div ±1.5 mV
      • 10 mV/div to 99.5 mV/div: ±0.35% (offset value-position) ±0.1 div ±1.5 mV
      • 100 mV/div to 1 V/div: ±0.35% (offset value-position) ±0.1 div ±15 mV
      • 1.01 V/div to 10 V/div: ±0.25% (offset value-position) ±0.1 div ±150 mV
    • Delay Between Any Two Channels (Typical): =100 ps (50 O, DC coupling and equal V/div at or above 10 mV/div)
    • Channel-to-Channel Isolation (Any 2 channels at equal Vertical Scale Settings) (Typical):
      • =100:1 at =100 MHz
      • =30:1 between 100 MHz and 2.5 GHz
      • > 20:1 between 2.5 and 3.5 GHz
  • Time Base System:
    • Time Base Range: 25 ps/div to 1000 s/div
    • Time Resolution (in ET/IT mode): 250 fs
    • Time Base Delay Time Range: 5 ns to 250 s
    • Channel-to-Channel Deskew: Range ±75 ns
    • Delta Time Measurement Accuracy: ((0.06 / sample rate) + (2.5 ppm × Reading)) RMS
    • Trigger Jitter (RMS):
      • 1.5 psRMS (typical) with enhanced triggering OFF
    • Jitter Noise Floor:
    • Time Base Accuracy: ±2.5 ppm + Aging
  • Acquisition System:
    • Real-Time Sample Rates:
      • 1 Channel (Max): 40 GS/s
      • 2 Channels (Max): 20 GS/s
      • 3-4 Channels (Max): 10 GS/s
      • Equivalent Time Sample Rate (Max): 4 TS/s (for repetitive signals)
    • Maximum Record Length Per Channel:
      • Standard Configuration:
        • 1 Channel: 50 M
        • 2 Channel: 25 M
        • 4 Channel: 12.5 M
      • Record Length Opt. 2RL:
        • 1 Channel: 125 M
        • 2 Channel: 50 M
        • 4 Channel: 25 M
      • Record Length Opt. 5RL
        • 1 Channel: 250 M
        • 2 Channel: 125 M
        • 4 Channel: 50 M
      • Record Length Opt. 10RL
        • 1 Channel: 500 M
        • 2 Channel: 250 M
        • 4 Channel: 125 M
  • Maximum Duration at Highest Real-Time Resolution (1 Channel):
    • Resolution: 25 ps (40 GS/s)
    • Max Duration with Standard Record Length and Sample Rate: 1 ms
    • Max Duration with Opt 2RL: 2 ms
    • Max Duration with Opt 5RL: 5 ms
    • Max Duration with Opt 10RL: 10 ms

 

Package Includes :

  • Operation Manual (QR Link)
  • Service Manual (QR Link)
  • Quick Reference (QR Link)
  • Product Software (QR Link)
  • Power Cord
  • Mouse
  • Accessory Pouch (installed)
  • Front Cover (installed)
  • Oscilloscope Probe (Qty 4)

 

 

Additional information

Lead Time

5-7 days

Packaging

Box

Brand

Tektronix

PRODUCT INQUIRY

Please enable JavaScript in your browser to complete this form.

Reviews

There are no reviews yet.

Be the first to review “Tektronix DPO7254 Digital Phosphor Oscilloscope”

Your email address will not be published. Required fields are marked *