Description
Fluke ESA615 230V Electrical Safety Analyzer
Fluke ESA615 Electrical Safety Analyzer brings fast and simple automated testing to a portable analyzer for healthcare technology management professionals that perform electrical safety testing on medical equipment both in the field and in facilities. Whether it is simple testing or comprehensive analysis, Fluke ESA615 can do it all. This multifaceted device performs all primary electrical safety tests, including line (mains) voltage, ground wire (protective earth) resistance, insulation resistance, device current, and lead (patient) leakage tests. It also offers ECG simulation and pointヨto-point voltage, leakage, and resistance tests. Versatile to global electrical safety standards of choice, ESA615 tests to ANSI/AAMI ES1, NFPA- 99, IEC62353 (VDE751) IEC60601-1 (2nd and 3rd editions) and AS/NZS 3551. The ESA615 is an allin-one solution with a multimeter, safety analyzer and ECG simulator in a single test instrument.
Fluke ESA615 Easy to Use
Automated
Pre-set templates allow you to test to the global standard of your choices at the push of a button. Let the unit guide you through the test steps quickly and accurately in three simple steps:
- Select the test sequence corresponding to your standard of choice
- Initiate the automated test sequence.
- Store the results on-board or wirelessly export to your PC in seconds.
It is that easy. The automated test sequences are easily customized to suit individual testing requirements.
Portable
Fluke ESA615 is a small, lightweight analyzer with an integrated handle to carry from place to place for on-the-go field service. It is designed for operation in tight spaces, and is easy to fit on any cart. A light, protective carrying case makes it easy to store and transport.
Simple
A push-button interface allows quick access to highly-comprehensive functions and features, and an intuitive interface guides the user through tests. Fluke ESA615 features a large display for clear indication of available functions, set-up criteria, device under test receptacle conditions, and test results. Data can be entered quickly with a plugヨand-play keyboard, barcode scanner and/ or on-board data entry interface. Data archival is fast and simple with wireless communication or through a removable memory card with capacity for thousands of test results.
Features Fluke ESA615 :
- On-board automation with automated test sequences for rapid testing and easy compliance to key global electrical safety standards (ANSI/AAMI ES1 (NFPA-99), IEC62353 (VDE751), IEC60601-1 2nd and 3rd editions, and AS/NZS 3551)
- Portable, ergonomic design with an integrated handle and tilt stand
- Human-factors-designed user interface for streamlined testing
- ECG waveform tests and dual-lead measurements combine the functionality of a simulator, multimeter and safety analyzer in a single test tool
- 20 A at 120 V current capability
- Five applied parts jacks and easy ECG snap connection; optional expander box for up to 12-lead ECG testing
- Easy data entry through barcode scanner, external keyboard or on-board keypad
- Wireless communication plus removable memory card for fast and convenient data storage and exchange
- Replaceable mains fuses keep your unit in the field and out of the repair shop
- Custom language selections include English, French, German, Spanish, Italian and Portuguese
- Large, easy-to-read display with adjustable contrast
- Rigorously tested for rugged field applications, with CE and CSA in addition to Fluke qualityラruggedness for long-term reliability
Specifications Fluke ESA615
Voltage |
|
Range (mains voltage) | 90 V ac rms to 132 V ac rms |
Range (accessible voltage) | 0 V ac rms to 300 V ac rms |
Accuracy | ± (2 % of reading + 0.2 V) |
Voltage tests | Mains and point to point |
Earth resistance |
|
Modes | Two-Wire |
Test current/Ranges/Accuracy | > 200 mA ac / 0 O to 2 O / ± (2 % of reading + 0.015 O) |
Resistance tests | Earth resistance and point to point |
Equipment current |
|
Mode | AC rms |
Range/Accuracy | 0 A to 20 A ± (5 % of reading + (2 counts or 0.2 A, whichever is greater)) |
Duty cycle | 15 A to 20 A, 5 min. on/5 min. off 10 A to 15 A, 7 min. on/3 min. off 0 A to 10 A continuous |
Leakage current |
|
Modes ( Modes are available in all leakage tests with the exception of MAP leakages that are available only in true-rms) |
AC + DC (True rms) AC only DC only |
Patient load selection (input impedance) | AAMI ES1-1993 IEC 60601: |
Crest factor | = 3 |
Ranges | 0 µA to 199.9 µA 200 µA to 1999 µA 2 mA to 10 mA |
Frequency response/accuracy | DC to 1 kHz / ± (1 % of reading + (1 µA or 1 LSB, whichever is greater)) 1 kHz to 100 kHz / ± (2 % of reading + (1 µA or 1 LSB, whichever is greater)) 1 kHz to 5 kHz (current > 1.6 mA) / ± (4 % of reading + (1 µA or 1 LSD, whichever is greater)) 100 kHz to 1 MHz / ± (5 % of reading + (1 µA or 1 LSB, whichever is greater)) |
Accuracy for Isolation, MAP, Direct AP, Alternative AP, and Alternative Equipment leakage tests all ranges are: | At 120 V ac + (2.5 µA or 1 LSD, whichever is greater) For Alternative equipment, Alternative AP, and Direct AP leakage tests, the leakage values are compensated for nominal mains as per 62353. Therefore, the accuracy specified for other leakages is not applicable. |
Leakage tests | Ground wire (earth) Chassis (enclosure) Lead to ground (patient) Lead to lead (patient auxiliary) Lead isolation (mains on applied part) Direct equipment Direct applied part Alternative equipment Alternative applied part Point to point |
Mains on applied part test voltage | 100 % ± 7 % of Mains for AAMI, current limited to 1 mA ± 25 % per AAMI 100 % ± 7 % of Mains for IEC 62353 current limited to 3.5 mA ± 25 % per IEC 62353 100 % ± 7 % of Mains for IEC 60601-1 current limited to 7.5 mA ± 25 % per IEC 60601-1 |
Differential leakage | |
Ranges | 75 µ A to 199 µA 200 µA to 1999 µA 2 mA to 20 mA |
Accuracy | ± (10 % of reading + (2 counts or 20 µA, whichever is greater)) |
Insulation resistance |
|
Ranges/Accuracy | 0.5 MO to 20 MO / ± (2 % of reading + 0.2 MO) 20 MO to 100 MO / ± (7.5 % of reading + 0.2 MO) |
Source test voltage | 500 V dc or 250 V dc (+ 20 %, -0 %) 2.0 ± 0.25 mA short-circuit current |
Insulation resistance tests | Mains-PE, AP-PE, Mains-PE, Mains-NE (non-earthed accessible conductive part) and AP-NE (non-earthed accessible conductive part) |
ECG performance waveforms |
|
Accuracy | ± 2 % ± 5 % for amplitude of 2 Hz Square wave only, fixed @ 1 mV Lead II configuration |
Waveforms | Rates: ECG complex: 30 BPM, 60 BPM, 120 BPM, 180 BPM, and 240 BPM Ventricular fibrillation: |
Test standards |
|
Available selections | ANSI/AAMI ES-1, IEC62353, IEC60601-1, and AS/NZS 3551 |
Built-in test sequences |
|
IEC60601-1 3rd Edition | Patient Monitor, Defibrillator, Infusion Pump, Ultrasound Device, Generic Device and System |
IEC62353 | Patient Monitor, Defibrillator, Infusion Pump, Ultrasound Device and Generic Device |
NFPA-99 (Hospital) | Patient Monitor, Defibrillator, Infusion Pump, Ultrasound Device and Generic Device |
ANSI/AAMI ES1 | Patient Monitor, Defibrillator, Infusion Pump, Ultrasound Device and Generic Device |
Communications |
|
USB device upstream port | Mini-B connector for control by a computer |
USB host controller port | Type A, 5 V output, 0.5 A max load. Connector for keyboard and barcode reader |
Wireless | IEEE 802.15.4 for control by a computer |
Modes of operation | Manual and remote |
Power ratings |
|
Mains voltage outlet | 120 V ac 230 V ac |
Mains voltage inlet power range | 90 V ac rms to 132 V ac rms 180 V ac rms to 264 V ac rms |
Maximum current | 20 A 16 A |
Hz | 47 to 63 Hz 47 to 63 Hz |
Environmental |
|
Operating temperature | 10 ºC to 40 ºC (50 ºF to 104 ºF) |
Storage temperature | -20 ºC to 60 ºC (-4 ºF to 140 ºF) |
Operating humidity | 10 % to 90 % non-condensing |
Altitude | 120 V ac mains supply voltage up to 5000 meters 230 V ac mains supply voltage up to 2000 meters |
Package Includes :
- Fluke ESA615 230 V ac Electrical Safety Analyzer
- (2) 1000V Hard Point Test Leads
- Power Cord
- USB PC Interface Cable
- User Manual On CD-ROM
- Carrying Case (G)
Additional information
Lead Time | 5-7 days |
---|---|
Packaging | Box |