Olympus Panametrics Epoch 650 Ultrasonic Flaw Detector
$4,600
Model : Epoch 650 Ultrasonic Flaw Detector
Description
Olympus Panametrics Epoch 650 Ultrasonic Flaw Detector
Olympus Panametrics Epoch 650 is a lightweight, portable flaw detector that is built to be rugged and flexible for almost any inspection. Some of the key physical features include: Large, full-frame VGA resolution transflective display for crisp clarity in indoor lighting and direct sunlight conditions. Excessive rubber bumpers on all four corners for shock absorption and anti-marring considerations. Four-point harness connection for chest strap “Tool-free” access to battery compartment and side I/O door.
Continuous standing position with right-angle clamp for increased stability from 0 to 180 degrees Side pant door for USB OTG connection and removable memory Standard internal rechargeable lithium-ion battery. Lightweight, ergonomic design for increased portability and ease of use Standard EPOCH 650 Digital ultrasonic flaw detector, AC or battery operated. Charger/AC adapter (100 VAC, 115 VAC, 230 VAC, 50 Hz or 60 Hz) Rechargeable lithium-ion battery Transport case USB cable Quick reference card Comprehensive operating manual (CD).
Description Olympus Panametrics Epoch 650
Economical Size, Quality Performance
The large, full VGA transflective display combined with our patented digital high dynamic range receiver provides a stable, striking A-scan representation in any lighting condition. Olympus Panametrics Epoch 650 is designed to meet the requirements of EN12668‑1 and allows a full range of standard and optional flaw detection features. Multiple onboard reporting tools and a comprehensive data filing system enable you to easily collect and report high quality inspection data. The rugged, ergonomic design allows use in nearly any inspection environment, while the flexible PerfectSquare™ pulser and highest number of digital filters in its class can tackle nearly any application.
Olympus Panametrics Epoch 650Digital Ultrasonic Flaw Detector combines Olympus’ industry leading conventional flaw detection capabilities with the efficiency of a highly portable, intuitive instrument. Olympus Panametrics Epoch 650 flaw detector’s blend of efficient menus and direct access keys allows you to take advantage of the highest quality flaw detection platform with exceptional ease of use.
Designed for All Inspection Environments
The EPOCH 650 is designed for use in nearly any inspection environment, from bench top testing in a laboratory to extreme outdoor and hazardous conditions. Designed for IP rating in either knob (IP66) or navigation pad (IP67) configurations, and tested to very high environmental and reliability standards, the EPOCH 650 allows users in any inspection environment to feel confident in both the performance and durability of the instrument.
Key Features Olympus Panametrics Epoch 650 :
- Designed to meet the requirements of ISO 22232-1
- PerfectSquareTM tunable square wave pulser
- Full screen A-scan mode
- Digital high dynamic range receiver
- Thirty digital filters for enhanced signal-to-noise ratio
- 2 kHz PRF for rapid scanning
- Knob or navigation pad adjustment configurations
- Large, full VGA sunlight readable display
- 15+ hours of battery life
- Standard dynamic DAC/TCG and onboard DGS/AVG
- Multiple on-board report formats
- MicroSD memory card for data transfers
- Optional Corrosion Module software with Encoded B-scan
- USB On-The-Go (OTG) for PC communication
- Alarm and VGA outputs
- Optional analog output
Specification Olympus Panametrics Epoch 650
Instrument Inputs/Outputs | USB Ports | USB On-The-Go (OTG) |
---|---|---|
RS-232 Port | Yes | |
Video Output | VGA output standard | |
Analog Output | 1 analog output (optional), Selectable 1 V/10 V Full Scale, 4mA max | |
Alarm Output | 3 alarm outputs, 5 V TTL, 10 mA | |
Trigger I/O | Trigger input, 5V TTL; Trigger output, 5V TTL, 10 mA max |
|
Encoder Inputs | 1-axis encoder line (quadrature – Corrosion Module mode only) | |
Environmental Ratings | IP Rating | Designed to meet the standards of the Ingress Protection (IP) rating number IP67 (navigation pad version) or IP66 (knob version) per IEC 60529-2004 (Degrees of Protection provided by enclosures – IP Code).
The product design was confirmed to meet the IP rating by means of Olympus internal design verification test process that occurs prior to the release of the product to production. |
Explosive Atmosphere | Safe operation as defined by Class I, Division 2, Group D, as defined in the National Fire Protection Association Code (NFPA 70), Article 500, and tested using MIL-STD-810F, Method 511.4, Procedure I. | |
Shock Tested | MIL-STD-810F, Method 516.5 Procedure I, 6 cycles each axis, 15g, 11 ms half sine. | |
Vibration Tested | MIL-STD-810F, Method 514.5, Procedure I, Annex C, Figure 6, general exposure: 1 hour each axis | |
Operating Temperature | –10 °C to 50 °C (14 °F to 122 °F) | |
Battery Storage Temperature | 0 °C to 50 °C (32 °F to 122 °F) | |
General | Overall dimensions (W x H x D) | 236 mm x 167 mm x 70 mm (9.3 in. x 6.57 in. x 2.76 in.) |
Weight | 1.6 kg (3.5 lb), including lithium-ion battery | |
Keypad | English, International, Japanese, Chinese | |
Languages | English, Spanish, French, German, Japanese, Chinese, Portuguese, Russian | |
Transducer connections | BNC or Number 1 LEMO | |
Data storage | 100,000 IDs onboard, removable 2 GB MicroSD card (standard) | |
Battery type | Single lithium-ion rechargeable standard | |
Battery life | 15 h to 16 h (lithium-ion) | |
Power requirements | AC Mains: 100 VAC to 120 VAC, 200 VAC to 240 VAC, 50 HZ to 60 Hz | |
Display type | Full VGA (640 x 480 pixels) transflective color LCD, 60 Hz update rate | |
Display dimensions (W x H, Diag.) | 117 mm x 89 mm, 146 mm (4.62 in. x 3.49 in., 5.76 in.) | |
Pulser | Pulser | Tunable Square Wave |
PRF | 10 Hz to 2000 Hz in 10 Hz increments | |
Energy settings | 100 V, 200 V, 300 V or 400 V | |
Pulse width | Adjustable from 25 ns to 5,000 ns (0.1 MHz) with PerfectSquare™ technology | |
Damping | 50, 100, 200, 400 Ω | |
Receiver | Gain | 0 to 110 dB |
Maximum input signal | 20 V p-p | |
Receiver input impedance | 400 Ω ± 5% | |
Receiver bandwidth | 0.2 MHz to 26.5 MHz at -3 dB | |
Digital filter settings | Thirty digital filter sets standard Seven ISO 22232-1:2020 compliant filters (0.2-10 MHz, 2.0-21.5 MHz, 8.0-26.5 MHz, 0.5-4 MHz, 0.2-1.2 MHz, 1.5-8.5 MHz, 5-15 MHz) |
|
Rectification | Full-wave, Positive Half-wave, Negative Half-wave, RF | |
System linearity | Horizontal: ± 0.5% FSW | |
Resolution | 0.25% FSH, amplifier accuracy ± 1dB | |
Reject | 0 to 80% FSH with Visual Warning | |
Amplitude measurement | 0 to 110% full screen height with 0.25% resolution | |
Measurement rate | Equivalent to PRF in all modes | |
Calibration | Automated calibration | Velocity, Zero Offset Straight Beam (First Backwall or Echo-to-Echo) Angle Beam (Soundpath or Depth) |
Test modes | Pulse Echo, Dual, or Through Transmission | |
Units | Millimeters, inches, or microseconds | |
Range | 3.36 mm to 13,388 mm (0.132 in. to 527.10 in.) @ 5,900 m/s (0.2320 in./μ) | |
Velocity | 635 m/s to 15240 m/s (0.0250 in./µs to 0.6000 in./µs) | |
Zero offset | 0 µs to 750 µs | |
Display delay | -59 mm to 13,401 mm (-2.320 in. to 526.97 in.) @ longitudinal velocity in steel | |
Refracted angle | 0° to 90° in 0.1° increments | |
Gates | Measurement gates | 2 fully independent gates for amplitude and TOF measurements |
Gate start | Variable over entire displayed range | |
Gate width | Variable from Gate Start to end of displayed range | |
Gate height | Variable from 2 to 95% full screen height | |
Alarms | Positive and Negative Threshold, Minimum Depth (Gate 1 and Gate 2) | |
Measurements | Measurement display locations | 5 locations available (manual or auto selection) |
Gate (1, 2) | Thickness, Soundpath, Projection, Depth, Amplitude, Time-Of-Flight, Min./Max. Depth, Min./Max. Amplitude | |
Echo-to-Echo | Standard Gate 2-Gate 1, Optional IF Gate Tracking | |
Other measurements | Overshoot (dB) value for DGS/AVG, ERS (equivalent reflector size) for DGS/AVG, AWS D1.1/D1.5 A, B, C and D values, Reject Value, Echo to RefdB values | |
DAC/TCG | Standard | |
DAC points | Up to 50 points, 110 dB dynamic range | |
Special DAC modes | Custom DAC (up to 6 curves), 20-80% View | |
Curved surface correction | Standard OD or Bar correction for Angle Beam measurements | |
Corrosion (optional) | Zero-cross measurement algorithm, V-Path correction, Single or Echo-to-Echo, Encoded B-scan |
Package Include :
- Olympus Epoch 650 Ultrasonic Flaw Detector
- (2) BNC Cables
- AC Adapter/Charger
- Power Cord
- PC Interface Cable
- USB PC Interface Cable
- User Manual On CD-ROM
- Carrying Case
Additional information
Lead Time | 5-7 days |
---|---|
Packaging | Box |
Reviews